IQ4/IQ4 Hub : PG 9309 Wiring and configuration

PG 9309 Auxiliary Contact Wiring :

PG9309 Aux wiring.jpg
IQ Panel 4 v4.2.1/higher Programming:

Settings > Advanced Settings > Installation > Devices > Security Sensors > Auto Learn Sensor:
1.      Auto Learn the PG9309 in by pressing the ‘Enroll Button’ for approximately 3 seconds then release the button. (The Amber LED must illuminate)

P1.png

2.      Confirm the ‘Sensor DL ID’.
3.      Select ‘Sensor Type’ as needed.

P2.png

4.      Select ‘Sensor Input’ as needed.

P3.png

5.    Select the ‘Sensor Group’ as needed ~ this MUST be done after selecting the ‘Sensor Input’

P4.png

6.      Complete the other programming options as needed, click ‘ADD NEW’.

WIRING AUXILIARY CONTACTS :

P5.jpg

Note : The EOL on PG 9309 is 5.6kohm

P6.jpg




Apr 17, 2025