It is possible to back up sensor programming and user codes from a
Qolsys IQ panel and restore those settings to a Qolsys IQ Panel 2. Once
a Qolsys IQ panel is backed up on the Partner Portal, this can be
applied to the Qolsys IQ Panel 2.
Important considerations
- Panel programming settings are not able to be applied from a Qolsys IQ panel to a Qolsys IQ Panel 2. Only user codes and sensors can be restored from a Qolsys IQ panel to a Qolsys IQ Panel 2.
- Though the Qolsys IQ Panel and DSC Touch are similar, a DSC Touch backup cannot be restored with a Qolsys IQ Panel or IQ Panel 2.
To perform the backup for a Qolsys IQ to a Qolsys IQ Panel 2:
**Important:**Any Image Sensors enrolled to the Qolsys
IQ will need to be deleted from the panel before the backup/restore
process, then re-enrolled after the process is complete.
- Verify the Partner Portal has an up-to-date backup with the current information. For more information on backing up the panel, see Backup a customer's panel, sensors, and settings. *Caution*: Only perform a backup if the customer's previous panel is still functioning. If the previous panel is not functioning, Alarm.com periodically saves the customer's panel and sensor settings as a backup in the event of a panel failure so there may already be a backup.
- If there is a successful backup of the old panel,power downthe old Qolsys IQ panel. The Qolsys IQ Panel 2 should also be powered down at this time.
- Apply the backup settings.
- Using the Partner Portal:
- Log into the Partner Portal.
- Find the customer account.
- Click Remote Toolkit.
- In the Command Catalog, click to expand General.
- Click Swap Panel.
- Click to select Sensor List and User Codes. Caution: Do not select Panel Settings, since panel programming settings are not able to be applied between a Qolsys IQ Panel and Qolsys IQ Panel 2**.**
- Click Apply.
- Using the MobileTech app.
- Log into MobileTech.
- Find the customer account.
- Tap Remote Toolkit.
- Tap Command Catalog.
- Tap to expand General .
- Tap Swap Panel.
- Tap to select Sensor List and User Codes. ***Caution: Do not select Panel Settings, since panel programming settings are not able to be applied between a Qolsys IQ Panel and Qolsys IQ Panel 2.*
- Tap Apply.
- Using the Partner Portal:
- Swap the module using the Partner Portal or MobileTech app. For more information about swapping the module, see Swap a module for a customer account. Caution: Do not select the Restore Settingscheckbox, as this can cause unexpected behavior to occur and the backup may be lost.
- Power up the Qolsys IQ Panel 2.
- Wait 15-30 minutes for the restore process to complete.
- Send a communication test to verify successful communication.