TSB #: 221024
DATE: 10/24/22
RE: IQ PANEL 2 & 2 PLUS - 2.7.2 SOFTWARE UPDATE
RELEASE NOTES & UPDATE INSTRUCTIONS
Release Notes:
Fixes/Improvements:
• Fixed an issue where the panel could report a false AC status
• Spanish / Portuguese / Turkish language improvements
• Corrected an issue where HSM2108 expanders connected to an IQ Hardwire PowerG (PGxHRDW8 /
PGxWLSHW8) would not allow N/C zone configuration
• KP-141/241 keypad improvements: Keypad is functioning as per the product manual when paired to IQ Panel
2/2+
• Corrected an issue with PG9905 and ADC Smarter Business Temperature Monitoring (SBTM) service
• Anti-Masking is now supported (On/Off) for PowerG motion sensors that support this feature
• Corrected an issue where the PowerG Keypad/Siren will not function properly when enabled for all sounds in
Partition 1
• Corrected an issue where Liftmaster GDO might not respond to commands properly from the Panel UI
• Improved Panel camera exposure for Alarm Videos
• Thermostat UI on the Panel can now show and set half degree increments (Celsius only)
• Improved Corbus keypad and PowerG Keypad functionality when EN Grade 2 is enabled
• Modified some sensor configurable fields to non-editable by the Master User
• Added support for the KP-140 to support silent arming
• New setting that when activated transmits a unique event code to the CS when the Power Down function is
used on the Panel
• Improvement to keep light state in sync on the panel for the Sengled Z-Wave Bulb V11-N13
• Corrected an issue where the Panel Camera and PIR cam images had an incorrect time stamp on the ADC
customer site
• PowerG Photoelectric Beam Detector DQ trouble now displays on ADC as offline/malfunction
• Added messaging on the Alarm.com history to show when Exit Delay is complete
• Includes PowerG Modem Firmware Version 2.42 (V2/V3) / 2.0.16.86(V4) - Radio Firmware Version 80.63 (V2/
V3) / 82.8(V4)
• Includes ADC Firmware v9.7.5
Update Instructions:
Compatibility Note: Your IQ Panel must be on software version 2.0.1 or higher and connected to Wi-Fi to install
this update wirelessly. Panels running 2.5.0 & 2.5.1 must be updated to 2.5.3 first, then they can be updated
directly to 2.7.2:
1- Swipe down from the top of the screen and touch “Settings"
2- Touch “Advanced Settings”
3- Enter a valid installer code (default is 1111)
4- Touch "Upgrade Software"
5 -Touch “Patch Tag” and enter the patch iqpanel2.7.2 then touch OK
6- Touch "Upgrade Using Network" (panel must be connected to Wi-Fi). Update will download and install
7- Once complete touch "OK" to reboot the panel. DO NOT TOUCH THE SCREEN. The update process will
take approximately 5 minutes. After the panel reboots the home screen will appear and the LED will turn green.