Please follow the steps below to enroll:
- Ensure the IQ Panel firmware is compatible ie. 4.4.0 or higher.
- Enter Advanced Settings in the IQ Panel, and select: “Installation > Devices > Automation > Auto Learn Devices”
- Press and hold the button on the IQ Smart Plug PG, until the LED turns orange (approximately 2 seconds), then release both buttons.
Note: If the IQ Smart Plug PG is not already plugged in at the time of enrollment, plugging it in will automatically broadcast the Power G ID to the panel after a few seconds.
- Enter the parameters of the device: Sensor Name: Select or enter a custom name. Pin Code: Leave this blank or enter the 8-digit pin code written on the device sticker. Activation LED: Enable or disable the status LED.
Resetting the Device - Factory reset
- Press and hold both buttons until the LED turns orange (approximately 2 seconds).
- Release both buttons.
- Press and hold both buttons again until the LED turns red (approximately 5 seconds), the LED will flash 3 times.
- Release both buttons.
Note, if the device was enrolled into an IQ Panel during the reset, it will need to be re-enrolled after the reset.