The IQ Panel contains 2 Hardwired Inputs, labeled HW1 and HW2., + and -. These inputs are designed to support Door/window contacts, motion detectors, or glass-breaks ONLY. If using a motion or glass-break, you must have an external power supply. The resister must be 4.7k Ohms ONLY. The inputs are normally open and require a 4.7k resister in series. The resisters are NOT included in the box with the IQ Panel and must be purchased separately.
What are HW1 and HW2 inputs for, and what type of resister do they need?
Contact Us
Not finding what you're looking for? Contact Us Directly